Not affiliated
A switch matrix connected to the feed of the antennas changes the pair of antennae during measurement of the signals. 2012;11:1610-1613. doi: 10.1109/LAWP.2012.2236293. Eight patients undergoing neoadjuvant chemotherapy for locally advanced breast cancer were imaged longitudinally …
We used CMOS transceiver chips instead of a high-precision pulse generator and high-speed oscilloscope; also, a master controller performs the role of switching matrix. Several research groups have studied microwave breast imaging systems that are noninvasive and not harmful to human as alternative early diagnostic breast cancer imaging methods. Barrière et al., “Towards a planar Microwave Tomography system for early stage breast cancer detection,” in, X. Zeng, A. Fhager, and M. Persson, “Effects of noise on tomographic breast imaging,” in, M. Xu, P. Thulasiraman, and S. Noghanian, “Microwave tomography for breast cancer detection on cell broadband engine processors,”, M. Haynes, J. Stang, and M. Moghaddam, “Microwave breast imaging system prototype with integrated numerical characterization,”, N. Simonov, S.-I. Reference [109] shows the image formation equations. The data was obtained from 15 patients. Not logged in Bond, B. D. Van Veen, and S. C. Hagness, “Estimation of the frequency-dependent average dielectric properties of breast tissue using a time-domain inverse scattering technique,”, S. Kharkovsky and R. Zoughi, “Microwave and millimeter wave nondestructive testing and evaluation—overview and recent advances,”, S. Y. Semenov and D. R. Corfield, “Microwave tomography for brain imaging: feasibility assessment for stroke detection,”, J. Wang, X. Wang, Z. Zhu, J. Huangfu, C. Li, and L. Ran, “1-D microwave imaging of human cardiac motion: an ab-initio investigation,”, O. P. Gandhi, Q.-X. X-ray mammography uses low-energy X-rays to create images of the breast. It uses a 2 port VNA, and takes approximately 90 seconds to scan. Thus, the production cost of our imaging system prototype may be less than 3,000. Thus, regular checkups and early detection of breast cancer are crucial. National Center for Biotechnology Information, Unable to load your collection due to an error, Unable to load your delegates due to an error, (a) 3D FDTD grid used for forward solution, (b) cylindrical tetrahedral element mesh used for reconstruction, Microwave imaging system located at the Advanced Imaging Center at Dartmouth Hitchcock Medical Center (DHMC). The Dartmouth group has developed a clinical prototype for active microwave imaging of the breast for the first time [18]. Microwave Theor. The data were obtained from seven different array heights for seven different frequencies at each array position. Three-dimensional microwave imaging of realistic numerical breast phantoms via a multiple-frequency inverse scattering technique.
However, the system still depends on a high-precision pulse generator and very high-speed oscilloscope and may require complicated switching circuits.
Figure 5(a) shows the dielectric properties of malignant tissue were similar to the results of previous works, unlike the dielectric properties of normal breast tissues in Figure 5(b). In the array rotation calibration method, two sets of measured data are received from a physically rotating antenna array, in which unwanted signals are almost the same [36]. Radiology. Other breast screening methods are adjuncts to mammography. A calibrated signal is obtained by subtracting one of the two sets of the signals from the other. Figure 4 depicts the dielectric properties of 85–100% adipose tissues as solid lines, 0–30% as dash-dot lines and 31–84% adipose tissues as dashed lines. Eng. University of Bristol team performed experimental and clinical study using UWB microwave radar imaging method for the first time [25]. Breast Cancer Detection-A Synopsis of Conventional Modalities and the Potential Role of Microwave Imaging. This is because malignant tissues contain much water and are more active than normal [40, 41].
An ultra-wideband signal is appropriate for these conditions. Med Phys. Figure 3 shows the dielectric properties of malignant and normal breast tissues from earlier studies. University of Bristol also presented a time-domain wideband adaptive beamforming to reduce clutter [134]. The intensity of a reconstruction image is calculated by moving the focal point from one position to another within the breast. Syst.—I. First, we review studies of breast tissue properties in the microwave region.
The authors declare that they have no competing interests. However, it has low resolution. IREA, National Research Council of Italy, has developed diagnostic and therapeutic strategies based on the use of electromagnetic fields at microwave frequencies for some years. Tech. Figure 23 shows the radar-based breast imaging system of MICRIMA which was founded in 2006 to develop and commercialize the technology of microwave radar breast imaging at the University of Bristol in the UK. A single system clock from the master controller drives all the 16 transceivers. The microwave image is formed by summing the filtered signals. Thus, in the National University of Ireland Galway they used preprocessing filter to compensate the path-dependent attenuation and phase effects.
ACTIVE MICROWAVE IMAGING FOR BREAST CANCER DETECTION G. Bindu, A. Lonappan, V. Thomas, C. K. Aanandan, and K. T. Mathew Department of Electronics Microwave Tomography and Materials Research Laboratory Cochin University of Science and Technology Kochi-682 022, India S. J. Abraham Department of Surgery Lourde Hospital Kochi, India Several published reports discuss that it risks exposure to radiation [3–6]. Scattered signals are measured in the frequency domain using VNA.
This is a preview of subscription content. The focal point is assumed to be .
Microwave imaging for biomedical applications is particularly interesting, mainly due to the fact that available range of dielectric properties for different tissues can provide important functional information about their health. Kim, J.-M. Lee, and S.-I. Prof. Paulsen and Prof. Meaney from Dartmouth College in the United States are one of the representative research groups. Figure 33 shows the restored image of 3D hemispherical breast model composed of a 2 mm thick skin, fat, and 3 mm radius tumor with 1,000 measurements when all possible noise sources are present, such as clock skew (±1% + 5 ps), clock jitter (1.6 ps), and white noise. The transceivers transmit a UWB pulse one at a time, and the rest of them receive the signal simultaneously, such that the total scan time can be dramatically reduced to 1.32 sec at 1.76 GHz sampling clock, while a typical scan time with a frequency domain system is more than 10 seconds. Get the latest public health information from CDC: https://www.coronavirus.gov. Medical applications of microwave imaging. Consequently, they achieved more clear images (Figure 17) [23].